Typical parts
Instrument housings & covers · Surgical-instrument metal parts (handles / links / clamps — not implants) · Optical / sensor brackets · Lab fixture plates
Zoryra Precision
Nan Dongguan, Lachin, Zoryra Precision machin estrikti metal pou ekipman medikal ak laboratwa: lojman enstriman, enstalasyon laboratwa, ak manch chirijikal enstriman/lyen/estrikti kranpon. Dimansyon onèt: ki pa enplantasyon, pa ITAR pa default. Yo ka mande rapò dimansyon, sètifikasyon materyèl, NDA, ak vizit faktori sou sitasyon an. Nou pa reklame pwosesis esteril, epi paj sa a pa montre nimewo sètifika envante.

Ilistasyon pwodwi pati CNC tipik — pa yon foto faktori twazyèm pati.
Zoryra Precision (泽锐精工) is a custom CNC machine shop in Dongguan, Guangdong, China. Invoice entity: Dongguan Zoryra Precision Manufacturing Co., Ltd.. Site zoryra.com; RFQ [email protected].
How quoting works: upload STEP / STL / IGES for an AI itemized reference (material, machining, lead-time tier shown separately). The reference is not an auto-charged contract price; fit-critical or 5-axis jobs can escalate to an engineer before PO.
Fulfillment: factory-direct in Dongguan, China, from 1 pc. International legs are sketched as courier (e.g. DHL / FedEx / UPS), air, or sea. Duties are typically extra unless DDP is agreed.
Honesty: this page does not publish invented ISO / AS / FDA numbers, and does not present other companies’ factory photos as Zoryra’s shop. Certificates and inspection packs follow the list both sides confirm.
Medical-adjacent jobs are still factory-direct Dongguan, China with the same AI itemized reference. Invoice entity remains Dongguan Zoryra Precision Manufacturing Co., Ltd. Book audits via contact — no stand-in plant photos.
Zoryra Precision machines non-implant metal parts in Dongguan, China for instrument OEMs, labs, and instrument-structure buyers. Brand: Zoryra Precision / 泽锐精工. Factory: Dongguan, Guangdong, China. Invoice entity: Dongguan Zoryra Precision Manufacturing Co., Ltd.
“Medical CNC” is often used to mean implants or registered devices. Our scope is narrower and honest: housings and covers for diagnostic/therapy instruments, lab fixtures, optical and sensor brackets, and metal structures on surgical instruments (handles, links, clamp blocks) — not implants, not a sterilization service, and not ITAR by default.
QA documents are quote ticks: material certs, dimensional reports, FAI, NDA. Factory visits can be scheduled via the contact page in Dongguan, China. We do not pad the page with other companies’ plant photos.
Aluminum and stainless (304 / 316 on RFQ) are typical. Passivation, anodize, and cleaning notes belong on the RFQ. We do not default to biocompatibility or cleanroom packaging unless both sides confirm an outsourced scope in writing.
Tolerances: structural fits often ±0.05 mm; sealed or guided interfaces often ±0.01–0.02 mm. Finer capability still follows the drawing and inspection list. Economy / Standard / Express tiers; Standard ≈ 10 days reference with finish on a production + air sketch.
Instrument housings typically mill in aluminum, then anodize or powder with mating faces masked. Lab fixtures more often run stainless with passivation on the RFQ. Handles, links, and clamp blocks on surgical instruments are quoted as machined parts — not a registered finished device and not an implant.
DFM should mark sealing faces, guide bores, window retainers, and grounding bosses. Cleaning notes (deburr grade, alcohol wipe, etc.) belong on the RFQ. The default line is not a cleanroom and not sterilization.
Material certs, dimensional reports, FAI, CMM, and NDA are quote ticks. Factory visits book Dongguan, China via contact. This page does not show invented FDA / ISO numbers.
Instrument housings & covers · Surgical-instrument metal parts (handles / links / clamps — not implants) · Optical / sensor brackets · Lab fixture plates
Structural fits ±0.05 mm common; sealed / guided interfaces often tighter (±0.01–0.02 mm). Fine capability to 0.001 mm when drawn — with optional CMM.
Material certs · Dimensional reports · NDA · Passivation / anodize notes
Structural fits ±0.05 mm common; sealed / guided interfaces often tighter (±0.01–0.02 mm). Fine capability to 0.001 mm when drawn — with optional CMM.
Materyèl · tolè kritik · sijè CNC onèt. Louvri yon kat pou yon ka oswa telechaje STEP pou fè yon kotasyon. Imaj yo se pati ilistrasyon, pa foto faktori twazyèm pati.

Non-implant · cutouts & bosses · dim. report optional

Handles / links / clamp structures (not implants) · stainless CNC · call out passivation

Slots & datum pads · see 316 bracket case · NDA on request

Diagnostic-adjacent structures · faces & holes per drawing · no implants

Mill-turn · non-implant · call out passivation on the RFQ

Machined ring · no optical coating · illustrative
Aliminyòm ak Nerjaveèi yo komen nan travay medikal-adjasan. Pasivasyon, anodize, ak nòt netwayaj dwe rive ak RFQ la — nou pa default nan yon reklamasyon "medikal-klas esteril".
Estrikti yo site sou chemen moulen/vire. Dokiman QA ak NDA yo ta dwe make anvan PO pou papye yo pa yon refleksyon nan bato a.
Lead time on the site is three tiers: Economy / Standard / Express. Standard is commonly ~10 days as a reference (production + air sketch, with the selected finish); Express is often ~6 days when material and finish allow.
Anodize, passivation, powder, and outsourced heat-treat add days on the production clock — put them on the RFQ instead of a verbal “few days.”
The clock starts at the agreed payment node, not at the moment the AI preview appears. PO and drawing revision follow the confirmation.
Passivation and powder add days. Standard ≈ 10 days reference with finish on a production + air sketch. Clock from the payment node.
Samples are paid pilots, not free medical samples.
Non-implant structures still need fit notes. Mark seal grooves, guide bores, window retainers, and grounding bosses on the PDF. Do not leave cleaning grade as a verbal aside.
Documents follow the ticks. Unticked does not mean a full device-registration pack. Audits are a Dongguan, China visit.
No. Instrument housings, lab structures, and surgical-instrument metal components (handles/links/clamps) only.
Yes — schedule a Dongguan, China visit via contact / engineering. We do not substitute other plants’ photos.
Machined handles, links, and clamp structures. Not a finished registered device and not sterilization.
Material certs, dimensional reports, FAI, NDA as quote ticks. We do not verbally promise files that are not on the list.
Yes, on RFQ. There is an anonymized 316 bracket case on the site.
Not by default. Put cleaning notes on the RFQ. Cleanroom pack only if a written outsource path is agreed.
Custom CNC in Dongguan, Guangdong, China. Brand Zoryra Precision / 泽锐精工. Invoice: Dongguan Zoryra Precision Manufacturing Co., Ltd. zoryra.com / [email protected].
Standard ≈ 10 days reference with finish (production + air sketch). Express depends on material/finish. Clock from the payment node.
Metal rings only by default. Lenses, coatings, and bonding are a separate outsource path, not in the CNC reference.
Not default. Put the spec and medium on the RFQ; we then review outsource.
On RFQ. Not the default Al/SS path — lead and tooling differ.
Not by default. We follow grade + material cert, not a biocompatibility claim.
No. Paid 1-pc pilots, same as the rest of the site.
AI Instant Reference Quote + engineering review within 12 business hours.
Imèl travay prefere ([email protected]). Imèl pèsonèl oke. Opsyonèl — telechajman an toujou mache.
Nou pral itilize imèl travay sa a sèlman pou voye atik sa a ak pou reponn kesyon jeni ou yo (sitasyon, tan livrezon, desen).