Heta jey Teko ~10 ára (prod + yvyty ta'anga) · Pya'e ~6 ára · kuatia ta'anga / DFM

Zoryra Precision

Pohãnohára & Ma'ẽha CNC (Non-Implant) | Zoryra Jojaha

In Dongguan, Chína, Zoryra Jojaha máquinakuéra kuarepoti yvyra'ã -pe pohãnohára ha ma'ẽha tembiporu: instrument housings, ma'ẽha mohenda, ha surgical-instrument handles/joaju/clamp yvyra'ã. Honest pa'ũ: non-implant, ani ITAR by ijypýpe. Tuichakue marandu, mba'e certs, NDA, ha óga jejapo jeju ikatu be requested on pe ñembohepy. We do ani je'e sterile processing, ha ko kuatiarogue ojapo ani ehechauka invented kuatia papapy.

  • Instrument housings Avañe'ẽme
  • Instrument structures
  • Lab fixtures
  • Optical mounts
Illustrative non-implant instrument róga ha ma'ẽha mohenda — Zoryra Jojaha, Dongguan, Chína

Mba'e apopyre illustration of heta jey CNC pehẽngue — ani a third-party óga jejapo photo.

Máva máquinakuéra it, ha moõ

Zoryra Precision (泽锐精工) is a custom CNC machine shop in Dongguan, Guangdong, China. Invoice entity: Dongguan Zoryra Precision Manufacturing Co., Ltd.. Site zoryra.com; RFQ [email protected].

How quoting works: upload STEP / STL / IGES for an AI itemized reference (material, machining, lead-time tier shown separately). The reference is not an auto-charged contract price; fit-critical or 5-axis jobs can escalate to an engineer before PO.

Fulfillment: factory-direct in Dongguan, China, from 1 pc. International legs are sketched as courier (e.g. DHL / FedEx / UPS), air, or sea. Duties are typically extra unless DDP is agreed.

Honesty: this page does not publish invented ISO / AS / FDA numbers, and does not present other companies’ factory photos as Zoryra’s shop. Certificates and inspection packs follow the list both sides confirm.

Medical-adjacent jobs are still factory-direct Dongguan, China with the same AI itemized reference. Invoice entity remains Dongguan Zoryra Precision Manufacturing Co., Ltd. Book audits via contact — no stand-in plant photos.

Zoryra Precision machines non-implant metal parts in Dongguan, China for instrument OEMs, labs, and instrument-structure buyers. Brand: Zoryra Precision / 泽锐精工. Factory: Dongguan, Guangdong, China. Invoice entity: Dongguan Zoryra Precision Manufacturing Co., Ltd.

“Medical CNC” is often used to mean implants or registered devices. Our scope is narrower and honest: housings and covers for diagnostic/therapy instruments, lab fixtures, optical and sensor brackets, and metal structures on surgical instruments (handles, links, clamp blocks) — not implants, not a sterilization service, and not ITAR by default.

QA documents are quote ticks: material certs, dimensional reports, FAI, NDA. Factory visits can be scheduled via the contact page in Dongguan, China. We do not pad the page with other companies’ plant photos.

Aluminum and stainless (304 / 316 on RFQ) are typical. Passivation, anodize, and cleaning notes belong on the RFQ. We do not default to biocompatibility or cleanroom packaging unless both sides confirm an outsourced scope in writing.

Tolerances: structural fits often ±0.05 mm; sealed or guided interfaces often ±0.01–0.02 mm. Finer capability still follows the drawing and inspection list. Economy / Standard / Express tiers; Standard ≈ 10 days reference with finish on a production + air sketch.

Instrument housings typically mill in aluminum, then anodize or powder with mating faces masked. Lab fixtures more often run stainless with passivation on the RFQ. Handles, links, and clamp blocks on surgical instruments are quoted as machined parts — not a registered finished device and not an implant.

DFM should mark sealing faces, guide bores, window retainers, and grounding bosses. Cleaning notes (deburr grade, alcohol wipe, etc.) belong on the RFQ. The default line is not a cleanroom and not sterilization.

Material certs, dimensional reports, FAI, CMM, and NDA are quote ticks. Factory visits book Dongguan, China via contact. This page does not show invented FDA / ISO numbers.

Why choose Zoryra · Pohãnohára & Ma'ẽha CNC (Non-Implant) | Zoryra Jojaha

Typical parts

Instrument housings & covers · Surgical-instrument metal parts (handles / links / clamps — not implants) · Optical / sensor brackets · Lab fixture plates

Tolerance guidance

Structural fits ±0.05 mm common; sealed / guided interfaces often tighter (±0.01–0.02 mm). Fine capability to 0.001 mm when drawn — with optional CMM.

Watch-outs

Material certs · Dimensional reports · NDA Avañe'ẽme · Passivation / anodize notes

Typical parts

  • Instrument housings & covers
  • Surgical-instrument metal parts (handles / links / clamps — not implants)
  • Optical / sensor brackets
  • Lab fixture plates
  • Precision interface blocks
  • Device mounting plates
  • Passivated stainless brackets
  • Sealing-face covers (no sterile claim by default)
  • Window / optic retainer rings (machined — no coating)
  • Hinge blocks / tray pivots
  • Knurled knobs / thumb screws (mill-turn)
  • Microscope stage plates
  • Window / optic retainer rings (machined — no optical coating)
  • Sample-holder frames
  • Grounding posts and bosses
  • Drawer / slide interfaces (machined seats)
  • Fluid-adjacent metal blocks (not a registered fluidic device)

Tolerance guidance

Structural fits ±0.05 mm common; sealed / guided interfaces often tighter (±0.01–0.02 mm). Fine capability to 0.001 mm when drawn — with optional CMM.

Watch-outs

  • Non-implant / non-ITAR only unless pre-cleared
  • Call out passivation / anodize and cleaning
  • Request CoC / dim reports at quote time

Typical medical / lab parts (non-implant, illustrative)

Mba'e · tuichavéva tol. · honest CNC pa'ũ. Eipe'a a kuatia -pe a mba'e or ehupi STEP to ñembohepy. Images ha'e pehẽngue illustrations, ani third-party óga jejapo shots.

Mba'ekuéra ha apeno (kuatia ta'anga governs)

Kuarepoti morotĩ ha kuarepoti ndojehekýiva ha'e heta on medical-adjacent tembiapo. Passivation, apeno, ha cleaning jehaipy tekotevẽ arrive ndive pe RFQ — we do ani ijypýpe to a “medical-grade sterile” je'e.

  • Al6061-T6 — Instrument housings, covers, optical mounts.
  • SS304 — Lab fixtures and general stainless structures.
  • SS316 — On RFQ; see the anonymized 316 bracket case.
  • Passivation — Call out on stainless RFQs.
  • Anodize — Aluminum cosmetics or corrosion; mask fits per drawing.
  • PEEK / engineering plastic — Insulating or heat pads on RFQ — not a default mill path.
  • Powder coat — Common on cosmetic covers; days sit on the clock.

Tembiapo tape

Yvyra'ã ha'e oñembohepy on molino/jere tape. QA kuatia ha NDA tekotevẽ be ticked mboyve PO so paperwork is ani an afterthought at emondo.

  1. Upload STEP + PDF; mark non-implant / non-ITAR if that is the intent.
  2. Tick CoC, dimensional report, FAI, NDA on the quote.
  3. DFM for sealing faces, guided fits, and finish keep-outs.
  4. Dongguan, China mill/turn; passivate or anodize as drawn.
  5. Optional CMM, then export sketch (courier / air / sea).

Lead-time mbohapy ára (jehecha — moneĩ governs)

Lead time on the site is three tiers: Economy / Standard / Express. Standard is commonly ~10 days as a reference (production + air sketch, with the selected finish); Express is often ~6 days when material and finish allow.

Anodize, passivation, powder, and outsourced heat-treat add days on the production clock — put them on the RFQ instead of a verbal “few days.”

The clock starts at the agreed payment node, not at the moment the AI preview appears. PO and drawing revision follow the confirmation.

Passivation and powder add days. Standard ≈ 10 days reference with finish on a production + air sketch. Clock from the payment node.

Samples are paid pilots, not free medical samples.

Pa'ũ ha mba'e we do ani je'e

  • In scope: non-implant instrument structures, lab fixtures, instrument metal components.
  • Out of scope: implants, finished registered devices, sterile/cleanroom pack unless a written outsource path is agreed.
  • No invented FDA / ISO numbers.
  • Still out of scope: implants, sterilization, cleanroom pack unless written outsource, finished registered devices, invented FDA numbers.

DFM: seals, guides, cleaning notes

Non-implant structures still need fit notes. Mark seal grooves, guide bores, window retainers, and grounding bosses on the PDF. Do not leave cleaning grade as a verbal aside.

  • Seal-groove depth and chamfers on the drawing. No leak test unless the RFQ says so.
  • Guide bores with H7-style fits need the datum scheme too.
  • Window retainers are metal only — optics/coatings are a separate outsource conversation.
  • Passivate / anodize / powder: mark keep-outs.
  • Deburr grade (e.g. break sharp edges) in the notes.
  • State non-implant / non-ITAR on the RFQ so it is not mis-triaged.

QA documents and factory visit

Documents follow the ticks. Unticked does not mean a full device-registration pack. Audits are a Dongguan, China visit.

  • Material cert: grade / heat as ticked.
  • Dimensional report: confirmed list, not silent 100%.
  • FAI: first article or gauge plates.
  • CMM: sealing flatness or guide coaxiality when listed.
  • NDA and visit: via contact.

Related

FAQ

Do you make implants?

No. Instrument housings, lab structures, and surgical-instrument metal components (handles/links/clamps) only.

Can we audit the factory?

Yes — schedule a Dongguan, China visit via contact / engineering. We do not substitute other plants’ photos.

Which surgical-instrument parts?

Machined handles, links, and clamp structures. Not a finished registered device and not sterilization.

Which QA documents?

Material certs, dimensional reports, FAI, NDA as quote ticks. We do not verbally promise files that are not on the list.

Can you machine SS316?

Yes, on RFQ. There is an anonymized 316 bracket case on the site.

Sterile / cleanroom?

Not by default. Put cleaning notes on the RFQ. Cleanroom pack only if a written outsource path is agreed.

Who/where is Zoryra?

Custom CNC in Dongguan, Guangdong, China. Brand Zoryra Precision / 泽锐精工. Invoice: Dongguan Zoryra Precision Manufacturing Co., Ltd. zoryra.com / [email protected].

Lead time?

Standard ≈ 10 days reference with finish (production + air sketch). Express depends on material/finish. Clock from the payment node.

Do window retainers include optics?

Metal rings only by default. Lenses, coatings, and bonding are a separate outsource path, not in the CNC reference.

Leak / pressure test?

Not default. Put the spec and medium on the RFQ; we then review outsource.

PEEK?

On RFQ. Not the default Al/SS path — lead and tooling differ.

Biocompatibility cert?

Not by default. We follow grade + material cert, not a biocompatibility claim.

Free samples?

No. Paid 1-pc pilots, same as the rest of the site.

Upload CAD for an itemized reference

AI Instant Reference Quote + engineering review within 12 business hours.

Other industries

AIÑembohepyÑanduti veve
PDF Avañe'ẽme

Tembiapo ñanduti veve ojeiporavovéva (téra@atýra.com). Personal mail is OK. Eipotárõ — pe emboguejy gueteri tembiapo.

We’ll eiporu ko tembiapo ñanduti veve añoite to emondo ko item ha to answer nde mba'eapohára questions (ñembohepy, ára oñekotevẽva, kuatia ta'anga).

Pohãnohára CNC | Non-Implant Housings Instrument Pehẽngue | Zoryra Jojaha