Umgangatho oqhelekileyo ~iintsuku ezili-10 (ukuyila + air sketch) · Ngokukhawuleza ~iintsuku ezi-6 · umzobo / DFM

2026-08-10 · 4 min

Problem: AI Cold Plate Flatness Fails After Finish — Keep the Thermal Face Clean

Problem: accelerator cold plates meet thickness in-process, then after anodize or plating the contact face bows past 0.05–0.1 mm and TIM / liquid interface leaks heat.

Root cause: whole-part cosmetic finish with no masking; copper chosen late without lead-time buffer; sealing ports underspecified on the PDF.

Fix: as-machined thermal face; mask threads / ports; lock Al vs Cu on the first quote; sample flatness before ship.

Lead sketch: Standard ≈ 8–10 days with finish; Express when blank + light finish allow. Courier days stay separate.

Next: open the AI hardware industry page, then upload STEP + PDF on the quote page with flatness callouts.

Ixabisole-AIEmail
PDF

I-imeyile yomsebenzi iyathandwa ([email protected]). I-imeyile yomntu iyavunyelwa. Ngokuzithandela — ukukhuphela kusebenza.

Siza kusebenzisa le imeyile yomsebenzi kuphela ukuthumela le nto kunye nokuphendula imibuzo yakho yobunjineli (ixabiso, ixesha lokuikhokela, imizobo).

Problem: AI Cold Plate Flatness Fails After Finish — Keep the Thermal Face Clean — Zoryra Precision