Типичен стандард ~10 дена (производство + воздушен скиц) · Експрес ~6 дена · цртеж / DFM

2026-08-10 · 4 min

Problem: AI Cold Plate Flatness Fails After Finish — Keep the Thermal Face Clean

Problem: accelerator cold plates meet thickness in-process, then after anodize or plating the contact face bows past 0.05–0.1 mm and TIM / liquid interface leaks heat.

Root cause: whole-part cosmetic finish with no masking; copper chosen late without lead-time buffer; sealing ports underspecified on the PDF.

Fix: as-machined thermal face; mask threads / ports; lock Al vs Cu on the first quote; sample flatness before ship.

Lead sketch: Standard ≈ 8–10 days with finish; Express when blank + light finish allow. Courier days stay separate.

Next: open the AI hardware industry page, then upload STEP + PDF on the quote page with flatness callouts.

AIЦитатEmail
PDF

Препорачлива е работна е-пошта (име@компанија.com). Лична е-пошта е во ред. Опционално — преземањето сепак функционира.

Ќе ја користиме оваа работна е-пошта само за да го пратиме овој предмет и да одговориме на вашите инженерски прашања (попис, време на изработка, цртежи).

Problem: AI Cold Plate Flatness Fails After Finish — Keep the Thermal Face Clean — Zoryra Precision